Metal Mountain Equipment

5350 Gallon 20 foot ISO Storage Unit / 150 PSI Cryogenic Storage / LNG / LOX / LIN

Sold

This unit is no longer available. Similar equipment is listed below — or tell us what you're looking for and we'll connect you when a match lands.

Browse all Cryogenic Bulk Storage Tanks available now →
5350 Gallon 20 foot ISO Storage Unit / 150 PSI Cryogenic Storage / LNG / LOX / LINUsed

Specifications

ManufacturerCryogenic Intermodal
ModelTVAC IMO Type 7
ConditionUsed
Capacity5,350 Gallons
Working Pressure150 PSI
Inner Shell MaterialSA-240, GR 304N
Design CodeASME B & PVC, DOT MC-338, GCA-341, AAR-600, IMDG
Tare Weight16,650 Lbs
Dimensions20 foot
Gas ServiceLiquid Nitrogen (LIN), Liquid Oxygen (LOX), Liquid Argon (LAR), Liquefied Natural Gas (LNG), Acetylene
LocationWaxahachie, TX, United States
Stock #GE4S-1219

Description

5350 Gallon 20 foot ISO Storage Unit / 150 PSI Cryogenic Storage / LNG / LOX / LIN

Freshly retested Cryogenic Intermodal TVAC IMO Type 7 cryogenic ISO tank, rated for 150 PSI working pressure with 5,350 gallon capacity. This 20-foot intermodal unit is multi-service compatible with LIN, LOX, LAR, LNG, and C2H2, built to ASME B & PVC, DOT MC-338, GCA-341, AAR-600, and IMDG codes. Available for sale or rent.

Technical Specifications

Capacities: 5,350 Gallons

Tare Weight: 16,650 Lbs

Maximum Gross: 67,196 Lbs

Working Pressure: 150 PSI

Test Pressure: 254 PSI

Design Code: ASME B & PVC, DOT MC-338, GCA-341, AAR-600, IMDG

Inner Shell Material: SA-240, GR 304N

Inner Shell Thickness: .375,.44, &.50

Outer Shell Material: A0607, GR-50

Fitting Plumbing: 304 SS Sch 5 (Sch 40 under 1/2") piping

Thermal Performance: <.33 NER/day (LIN)

Insulation: Vacuum space with multilaminar insulation

Service Temperature: 100 degrees Fahrenheit to - 320 degrees Farenheit

Hold Times

54 Days LIN at 80 percent = 28,210 Lbs

79 Days LOX at 85 percent = 41,500 Lbs

64 Days LAR at 84 percent = 50,150 Lbs

82 Days LNG at 81 percent = 15,050 Lbs

168 Days C2H2 at 81 percent = 20,160 Lbs

Inspection, shipping & payment

Inspection Pre-purchase inspections are welcome during normal business hours by appointment arranged in advance. We can provide complimentary transportation from DFW Airport and back if you would like to send someone to see the equipment in person. We can also walk through the item over a video call for domestic or international buyers. We are on US Central Time. Shipping and loading The equipment is located at our yard south of Dallas, Texas. We can assist with shipping arrangements. Loading is provided at no charge for equipment under 15,000 lb when scheduled in advance. Equipment over 15,000 lb requires a crane, which is arranged and paid for by the buyer. Payment Payment in full is required FOB our yard in South Dallas. A verifiable cashier's check is accepted for collection in person. For release to a third-party shipper we require a wire transfer cleared in our account before the equipment leaves the yard.

Terms set by Gas Equipment 4 Sale.

Sold

Looking for something similar? We know who has one.

Available for Rent
LocationWaxahachie, TX, United States
Stock #GE4S-1219

Have one like this? Sell it on Metal Mountain →

Seller

Gas Equipment 4 Sale

Waxahachie, TX, United States

Verified

Business and location confirmed by Metal Mountain.

Questions buyers ask

What is the current vacuum reading, and what is the NER?

The listing states thermal performance of <.33 NER/day for LIN service but does not provide a current vacuum reading or recent test data. Before purchase, request the most recent vacuum gauge reading and ask when the vacuum was last serviced or certified, as this directly affects boil-off losses and operational economics.

What product has it held, and what can it be converted to?

The unit is listed as multi-service compatible with LIN, LOX, LAR, LNG, and C2H2, but the listing does not specify which product it most recently held. Conversion between these products typically requires cleaning, passivation if switching between oxygen and hydrocarbon service, and re-certification to verify material compatibility and cleaning adequacy—particularly critical when moving to or from oxygen service where hydrocarbon contamination creates explosion risk.

Is the data plate legible, and is the U-1A available?

The listing does not address data plate condition or documentation availability. Request photos of the data plate to verify stamping legibility and ask the seller to provide the original ASME U-1A Manufacturer's Data Report and any subsequent inspection or retest records, as these are required for regulatory compliance and re-certification in most jurisdictions.

What is involved in relocating and re-commissioning it?

This is a standard 20-foot ISO container with a tare weight of 16,650 Lbs, transportable by standard container chassis, but the listing does not specify current rigging or loading requirements at the Waxahachie location. Re-commissioning typically involves vacuum integrity verification, pressure testing to confirm the 254 PSI test pressure rating, safety valve calibration, and product-specific cleaning or passivation depending on your intended service and what it previously held.

General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.

Be first to see equipment like this

New matching inventory, straight to your inbox. Unsubscribe anytime, no spam.

Email this

Similar equipment available now

Comparable units currently listed on Metal Mountain.