Metal Mountain Equipment

Vaporizer 55,000 SCFH, 700 PSIG, low profile, ambient temperature, skid-based. Brand new

Vaporizer 55,000 SCFH, 700 PSIG, low profile, ambient temperature, skid-based. Brand newNew

Specifications

ManufacturerCCH Equipment Co
ModelHBVP-55K-AL-112-8X14-P-6-08
Year2024
ConditionNew
Flow Rate55,000 SCFH
MAWP700 PSIG
TypeAmbient temperature, natural convection
Construction CodeASME B31.3
Connections1-1/2" and 2" ANSI CL300 RF W/N flange
ConfigurationLow profile, skid-based
Gas ServiceLiquid Nitrogen (LIN), Liquid Oxygen (LOX), Liquid Argon (LAR), Liquefied Natural Gas (LNG)
LocationWaxahachie, TX, United States
Stock #GE4S-1148

Description

Vaporizer 55,000 SCFH, 700 PSIG, low profile, ambient temperature, skid-based. Brand new

This is a new 2024 CCH Equipment HBVP-55K ambient air vaporizer rated for 55,000 SCFH at 700 PSIG maximum allowable working pressure. Built to ASME B31.3 standards with all-aluminum construction, it converts cryogenic liquids—Liquid Oxygen (LOX), Liquid Nitrogen (LIN), Liquid Argon (LAR), and Liquefied Natural Gas (LNG)—into gaseous form using natural convection. The unit is cleaned, sealed, and oxygen-tagged per CGA G-4.1 standards and ships ready for industrial gas and clean energy applications.

All-aluminum design for corrosion resistance and long service life

Alloy 6063 extrusions, Alloy 6061 structural members, and Alloy 5052 piping components

Welded base with crimped fin array for thermal flexibility and durability

Wide 12-inch center-to-center fin spacing with 4-inch gap for optimized natural convection

Combination of 8-fin and 16-fin, 8-inch diameter extrusions with internal fins for increased heat transfer

1-1/2” and 2” ANSI CL300 RF W/N flange connections for secure integration

Constructed to ASME B31.3 compliance

Technical Specifications

Maximum Allowable Working Pressure (MAWP): 700 PSIG

Seismic design per ASCE/SEI 7 (San Jose, CA regional standards)

Wind load design: rated for 120 mph per ASCE/SEI 7

Outlet temperature designed at 20°F approach to ambient

Units are cleaned, sealed, and oxygen-tagged in accordance CGA G-4.1 standards

The HBVP-55K Ambient Vaporizer is an excellent choice for:

Industrial gas distribution systems

LNG regasification and peak-shaving facilities

Hydrogen fueling stations and renewable energy projects

Steel manufacturing, electronics production, aerospace, and food processing industries

Inspection, shipping & payment

Inspection Pre-purchase inspections are welcome during normal business hours by appointment arranged in advance. We can provide complimentary transportation from DFW Airport and back if you would like to send someone to see the equipment in person. We can also walk through the item over a video call for domestic or international buyers. We are on US Central Time. Shipping and loading The equipment is located at our yard south of Dallas, Texas. We can assist with shipping arrangements. Loading is provided at no charge for equipment under 15,000 lb when scheduled in advance. Equipment over 15,000 lb requires a crane, which is arranged and paid for by the buyer. Payment Payment in full is required FOB our yard in South Dallas. A verifiable cashier's check is accepted for collection in person. For release to a third-party shipper we require a wire transfer cleared in our account before the equipment leaves the yard.

Terms set by Gas Equipment 4 Sale.

LocationWaxahachie, TX, United States
Stock #GE4S-1148

Have one like this? Sell it on Metal Mountain →

Seller

Gas Equipment 4 Sale

Waxahachie, TX, United States

Verified

Business and location confirmed by Metal Mountain.

Get Pricing

The seller will send you pricing directly.

Your info goes only to the seller of this equipment. No spam, ever.

Questions buyers ask

How do I size this vaporizer for my flow rate and duty cycle?

This unit is rated for 55,000 SCFH at 700 PSIG maximum allowable working pressure with an outlet temperature designed at 20°F approach to ambient. Ambient vaporizers are typically sized by determining your peak hourly flow requirement, applying a continuous duty derate factor (often 15–25% depending on climate), and verifying the outlet gas temperature meets your process or code minimum—ask the seller for the design basis ambient temperature and any available performance curves for different liquid feeds and operating pressures.

What happens to output in cold or humid conditions, and on continuous duty?

Ambient vaporizers rely entirely on natural convection and outside air temperature for heat input, so capacity drops significantly in cold weather—ask the seller for performance data at your site's design conditions. Frost and ice accumulation in humid conditions further reduces heat transfer and may require cycling or redundant capacity to maintain flow. Continuous duty typically requires oversizing compared to intermittent use, since the fins and structure cool down and approach the cryogenic liquid temperature rather than recovering between demand cycles.

Can this be put into a different gas service than it previously ran?

This unit is cleaned, sealed, and oxygen-tagged per CGA G-4.1 standards and is listed for use with Liquid Oxygen (LOX), Liquid Nitrogen (LIN), Liquid Argon (LAR), and Liquefied Natural Gas (LNG). Switching from inert or hydrocarbon service into oxygen service generally requires complete disassembly, cleaning, and re-certification to CGA G-4.1, while moving from oxygen service to nitrogen or argon typically requires only verification that no contamination has occurred—changing between chemically incompatible services or adding a service outside the original design may not be practical depending on metallurgy, original cleaning protocol, and code requirements.

What should I inspect on a used ambient vaporizer before buying?

This is a new 2024 unit with no prior service history. On any ambient vaporizer, inspect fin-to-tube joints for cracks or separation (particularly where crimped), check all aluminum welds and structural members for corrosion or damage, verify flange faces and connections are undamaged, and confirm that any oxygen cleaning certification is current and documented if required for your service—ask for hydrostatic test records, any metallurgical or PMI reports, and documentation of previous gas service and cleaning history.

General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.

Be first to see equipment like this

New matching inventory, straight to your inbox. Unsubscribe anytime, no spam.

Email this