TOMCO 12 Ton Liquid CO₂ Storage Tank | 350 PSI ASME Certified w/ Controls & Alarms
UsedSpecifications
Description
TOMCO 12 Ton Liquid CO₂ Storage Tank | 350 PSI ASME Certified w/ Controls & Alarms
This is a 2007 TOMCO₂ Equipment Company Systems 12 ton liquid CO₂ storage tank, built to ASME Section VIII, Div. 1 with a maximum allowable working pressure of 350 PSI at –40°F. The vacuum-insulated vessel includes a factory TOMCO₂ control system with Emerson Climate Technologies controller, managing pressure trips, temperature alarms, and safety cut-outs across multiple voltage configurations. Serial number 07371, National Board number 10091, final inspection completed 11/26/2007.
Technical Specifications
Manufacturer: TOMCO₂ Equipment Company Systems
Year Built: 2007
Serial Number: 07371
National Board (N.B.) Number: 10091
Capacity: 12 T
Maximum Allowable Working Pressure (MAWP): 350 PSI at –40°F
Test Pressure: 525 PSI
Shell Material: SA-612 N Carbon Steel
Insulation: Vacuum insulated for refrigerated liquid service
Design Code: ASME Section VIII, Div. 1
Control & Electrical System
Manufacturer: TOMCO₂ Control Systems (Emerson Climate Technologies controller)
Functions
High Pressure Trip Alarm
Low Pressure Cut-In / Cut-Out
High Condenser Temperature Alarm
Low Suction Pressure Alarm
High Temperature Cut-Out
Alarms & Indicators
LO Alarm
HI Alarm
Alarm Silence Button
Power Options (factory wired)
- 220V, 1 Phase, 60 Hz
- 220V, 3 Phase, 60 Hz
- 380V, 3 Phase, 50 Hz
- 480V, 3 Phase, 60 Hz
- 500V, 3 Phase, 60 Hz
- 575V, 3 Phase, 60 Hz
Inspection & Notes
Final inspection completed 11/26/2007
All service valves secured and piped for shipment
Electrical and safety systems verified at factory
Built for refrigerated liquid CO₂ storage with pressure control and safety redundancies
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
What is the current vacuum reading, and what is the NER?
The listing does not provide a current vacuum reading or normal evaporation rate (NER). You should request the most recent vacuum gauge reading and the NER in percentage-per-day; for a vacuum-insulated CO₂ tank this size, typical NER values range from 0.5% to 2.5% per day depending on insulation condition, but only a site measurement will tell you where this unit stands.
What product has it held, and what can it be converted to?
This tank was built for refrigerated liquid CO₂ storage and has been in CO₂ service. Conversion to other cryogenic fluids typically requires complete material compatibility review, cleaning/purging protocols, and may require re-rating or modification depending on the target product's temperature and pressure characteristics—consult with an ASME-authorized inspector before planning any service change.
Is the data plate legible, and is the U-1A available?
The listing confirms National Board number 10091 and serial number 07371, but does not state whether the data plate is physically legible or whether the original U-1A Manufacturer's Data Report is on hand. Request photos of the nameplate and confirmation that the U-1A (or a certified copy from the National Board) will transfer with the vessel.
What is involved in relocating and re-commissioning it?
The tank is currently secured and piped for shipment from Waxahachie, TX. Re-commissioning typically involves verifying vacuum integrity, pressure-testing per jurisdiction requirements, recalibrating the Emerson controller and all pressure/temperature safeties, and ensuring local electrical supply matches one of the factory-wired configurations (220V–575V options listed). Most jurisdictions will require a registered PE or authorized inspector to sign off before returning the vessel to service.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.