UsedSpecifications
ManufacturerThermal Care
ModelCentral Chiller TSR60A
ConditionUsed
LocationWaxahachie, TX, United States
Stock #GE4S-1178
Description
Thermal Care TSR60A central chiller with digital process water temperature monitoring and comprehensive alarm system. Features include NEMA-4 electrical enclosure, control transformer providing 115V/1/60 control voltage, and integrated compressor starters mounted in the control panel. System monitors process water supply and return temperatures, with fault protection for compressor, pump, tank low-level, high supply temperature, sensor failures, and E-stop conditions.
Technical Information
Water temperature readouts include: Process water supply Process water return
System alarms include:
Compressor fault
Pump fault
Chiller tank low-level
Supply temperature high
Process return sensor fault
Process supply sensor fault
E-Stop pressed
Electrical Features
NEMA-4 electrical enclosure
Control transformer to provide 115V/1/60 control voltage
Compressor starters (and pump starters if pump tank option is purchased) mounted in the control panel and wired to motors
Single-point main power block for simple wiring connection • Alarm horn and silence switch
Questions buyers ask
What condition is it in, and what service has it seen?
The listing states this unit is used but does not provide details about its service history, runtime hours, or previous application. Ask the seller for total operating hours, maintenance records, and what process it was cooling—particularly whether it handled clean water or a glycol mix, as this affects internal component condition.
What should I inspect before putting it into service?
Verify compressor oil level and condition, check refrigerant charge and look for signs of leaks at fittings and the condenser coil, and inspect the pump seals and impeller. Test all alarm functions listed—compressor fault, pump fault, low-level, high temperature, and sensor faults—as failed sensors or relays are common on used units and the digital monitoring system is only useful if the sensor chain is intact.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.
Inspection, shipping & payment
Inspection
Pre-purchase inspections are welcome during normal business hours by appointment arranged in advance. We can provide complimentary transportation from DFW Airport and back if you would like to send someone to see the equipment in person. We can also walk through the item over a video call for domestic or international buyers. We are on US Central Time.
Shipping and loading
The equipment is located at our yard south of Dallas, Texas. We can assist with shipping arrangements.
Loading is provided at no charge for equipment under 15,000 lb when scheduled in advance. Equipment over 15,000 lb requires a crane, which is arranged and paid for by the buyer.
Payment
Payment in full is required FOB our yard in South Dallas. A verifiable cashier's check is accepted for collection in person. For release to a third-party shipper we require a wire transfer cleared in our account before the equipment leaves the yard.
Terms set by Gas Equipment 4 Sale.