Steam Water Bath Vaporizer 600,000 SCFH / 1000 PSI / Vaporized for LNG
CEXI Model SHWB-750 steam water bath vaporizer rated for 600,000 SCFH at 1,000 PSIG MAWP. Previously used to vaporize LNG with an outlet temperature of 70°F and total heat load of 8,108,258 BTU/Hr. Unit is located in Waxahachie, TX and sold in used condition.
Technical Specifications
Model: SHWB-750
SCFH: 600,000
MAWP: 1,000 psig
MOP: 850 psig
Internal Temperature of O2: -297°F
Outlet Temperature of O2 70°F
Total Heat Load: 8,108,258 BTU/Hr
Heat Transfer Co-efficient 60.5 btu/hr/sq.ft/ Deg F 330°F
Surface Area: 405.79 sq/ft
Flow: 600,000 scfh
Mawp: 1,000 PSIG
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
What utilities and footprint does this unit need on site?
This unit requires a steam supply capable of delivering 8,108,258 BTU/Hr and a water source for the bath itself. Water bath vaporizers typically need floor space for the bath tank, piping manifolds, and access clearance around the coil bundle for inspection and tube replacement—ask the seller for overall dimensions and steam header requirements.
When does a water bath unit make more sense than ambient or electric?
Water bath units maintain stable outlet temperature regardless of ambient conditions, making them suitable for continuous high-flow applications like this 600,000 SCFH unit where ambient vaporizers would ice up or underperform in humidity or cold weather. Steam-heated baths are often preferred where process steam is already available and electric demand charges would be prohibitive at this heat load. They also handle cryogenic inlet temperatures like the -297°F specified here without the derating or capacity loss common in ambient fin-fan designs during winter or high-humidity operation.
What maintenance does the bath and heat source require?
Water bath vaporizers require periodic water treatment to control scale buildup on the heat transfer coils, which directly affects heat transfer efficiency. Steam traps, condensate return lines, and the steam control valve need regular inspection to maintain efficient heat transfer and prevent waterlogging. The bath water level, temperature controls, and any freeze protection systems require routine checks, and the coil bundle should be inspected for external corrosion or pitting where it contacts the bath water.
What should I inspect on a used water bath vaporizer before buying?
Inspect the coil bundle for leaks, external corrosion from bath water exposure, and internal erosion or pitting from cryogenic service—this unit saw -297°F inlet temperatures in LNG service. Verify the bath tank has no cracks or corrosion, confirm the MAWP stamping matches the 1,000 PSIG rating, and check whether pressure vessel certifications are current or require requalification. Ask the seller for hydrostatic test records, material certifications if oxygen-clean service is intended, and any maintenance history showing coil repairs or tube plugging that would reduce the 405.79 sq/ft surface area.