NewSpecifications
ManufacturerMason MFG
Model2812
Year2020
ConditionNew
Pressure Rating100 PSIG @ 250°F
Gas ServiceMixed Gases
LocationWaxahachie, TX, United States
Stock #GE4S-1091
Description
This is a Mason MFG Model 2812 shell and tube heat exchanger rated for 100 PSI at 250°F, manufactured in 2020 and offered in new condition. It is built for reliable thermal transfer in chemical processing, oil and gas, and other demanding process environments. The unit is designed for controlled heat exchange with hot oil, water, steam, and process fluids, suitable for integration into skid systems or standalone installations.
Specifications:
Design Type: Shell and Tube
MAWP: 100 PSI @ 250°F
MDMT: -20°F @ 100 PSI
Differential Design: Tubes and Sheets rated at 100 PSI
Maximum Mean Metal Temperature: Tubes rated at 150 PSI
Key Features:
Heavy-duty construction for long service life
Designed for consistent performance under thermal cycling
Suitable for hot oil, water, steam, and process fluid heat exchange
Ideal for integration into skid systems or standalone installations
Applications:
Ideal for use in chemical plants, refineries, food processing facilities, power generation plants, and other industrial process systems where controlled heat transfer is necessary.
Questions buyers ask
What condition is it in, and what service has it seen?
This unit is listed as new condition and was manufactured in 2020. No service history is provided, which is consistent with new equipment that has not been placed into operation.
What certification or inspection status does it carry?
No ASME stamp, National Board registration, or third-party inspection documentation is mentioned in the listing. Ask the seller whether this unit carries an ASME U-stamp and whether any inspection reports or manufacturer's data reports are available, as these are standard for pressure vessels in this service range.
What should I inspect before putting it into service?
Verify gasket condition and flange faces for damage from storage, confirm all nozzle threads or flanges are intact, and check for any corrosion if the unit has been stored outdoors or in humid conditions. Shell and tube exchangers typically require confirmation that tube-to-tubesheet joints show no signs of separation and that internal baffles are secure, which may require opening the unit if it has removable heads or bonnets.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.
Inspection, shipping & payment
Inspection
Pre-purchase inspections are welcome during normal business hours by appointment arranged in advance. We can provide complimentary transportation from DFW Airport and back if you would like to send someone to see the equipment in person. We can also walk through the item over a video call for domestic or international buyers. We are on US Central Time.
Shipping and loading
The equipment is located at our yard south of Dallas, Texas. We can assist with shipping arrangements.
Loading is provided at no charge for equipment under 15,000 lb when scheduled in advance. Equipment over 15,000 lb requires a crane, which is arranged and paid for by the buyer.
Payment
Payment in full is required FOB our yard in South Dallas. A verifiable cashier's check is accepted for collection in person. For release to a third-party shipper we require a wire transfer cleared in our account before the equipment leaves the yard.