Servomex Oxygen Analyser Skid
Servomex 01800B1GEN oxygen analyser skid rated 110-240V, 50/60Hz, 50VA. Unit includes an integrated Cash Valve Type FR, 1-1/2", set at 60 PSI with a range of 30-100 PSI and maximum inlet pressure of 400. Analyser features dual ranges: 0-10 and 0-25.
SERVOMEX GROUP LTD
1800
OXYGEN ANALYSER
Technical Specifications
MODEL NO: 01800B1GEN
RATING: 110-240 V~
50/60 HZ 50VA
RANGE 1: 0-10
RANGE 2: 0-25
DIE-CASTING
01800/315/0
LM25TF
Cash Valve
Type: FR
Size: 1-1/2"
Set: 60PSI
Range: 30-100 PSI
Max Inlet Press: 400
S/N: 3789GH0029
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
What capacity and product purity does it produce?
This is an oxygen analyzer, not a production unit—it measures oxygen concentration in a process stream. The unit offers dual measurement ranges of 0-10 and 0-25 O2. Analyzer capacity and response time are not specified in the listing; ask the seller for sample flow requirements and response time specifications if continuous monitoring duty cycle matters for your application.
What utilities, footprint and power draw does it require?
The skid requires 110-240V, 50/60Hz single-phase power at 50VA maximum draw. Physical dimensions and weight are not provided in the listing. Oxygen analyzers of this type typically require sample gas conditioning (pressure reduction, filtration, and sometimes drying) before the measurement cell, which this unit addresses with the integrated Cash Valve pressure regulator set at 60 PSI; maximum inlet pressure is 400 PSI.
How long was it in service, how long has it been down, and how was it preserved?
Service history, decommission date, and preservation method are not disclosed in the listing. Ask the seller for the unit's operating history and whether the measurement cell was stored with inert gas or conditioned air. Oxygen analyzer sensors degrade differently in storage depending on technology—knowing the sensor type and its exposure history will help assess whether recalibration or cell replacement is needed before commissioning.
What is realistically involved in relocating and re-erecting it?
This is a skid-mounted instrument package, so rigging and transport should be straightforward once dimensions and weight are confirmed with the seller. The unit will require recalibration with span gases after relocation, and the sensor should be evaluated for drift or contamination depending on storage conditions. Verify that your process sample pressure and composition are compatible with the inlet pressure limits and that the 0-10 and 0-25 ranges suit your monitoring requirements.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.