What is the MAWP and capacity at service pressure?
The shell MAWP is 600 PSIG at 650°F. The listing does not provide volume capacity, water capacity, or internal dimensions. Ask the seller for tank volume in gallons or cubic feet, as well as shell diameter and length, to determine if this meets your storage requirements.
What is the requalification or inspection status?
The listing does not provide current inspection records, hydro test dates, or certification status. ASME pressure vessels typically require periodic internal and external inspection per the National Board Inspection Code or jurisdictional requirements, with intervals often determined by the authorized inspector and operating conditions. Request documentation of the most recent hydrostatic test, NB-23 forms if applicable, and any thickness testing results.
What should I inspect before putting it into service?
Conduct a visual internal and external examination for corrosion, pitting, denting, and weld integrity, paying particular attention to shell seams, nozzle connections, and support attachments. Ultrasonic thickness testing should verify that remaining wall thickness meets minimum design requirements at the MAWP you intend to operate. Pressure relief devices must be removed, inspected or replaced, and set to your operating conditions, and all threaded connections and flanges should be examined for thread condition and gasket seating surfaces before hydrostatic testing and return to service.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.