PNEUMATECH HEATLESS REGENERATIVE AIR DRYER WITH 1 150 PSI Silvan Pneumatic Tank
UsedSpecifications
Description
PNEUMATECH HEATLESS REGENERATIVE AIR DRYER WITH 1 150 PSI Silvan Pneumatic Tank
Pneumatech PHS-2000 heatless regenerative air dryer rated for 2600 SCFM at 150 PSIG maximum pressure, manufactured in 1996. The system operates on 115V-1PH-60HZ power with a purge pressure of 55 PSIG and uses 825 lbs of desiccant per tower (AA2/5 and MC 4A). Includes one 150 PSI Silvan pneumatic tank (M.A.W.P 150 PSI at 450°F, M.D.M.T -20°F at 150 PSI, customer part number PV-1054).
Heatless Regenerative Air Dryer
Capacity: 2600 SCFM
Purge Pressure: 55 PSIG
Max. Pressure: 150 PSIG
Voltage: 115V-1PH-60HZ
Desiccant: AA2/5
Desiccant Weight: 825 LBS/Tower
Desiccant: MC 4A
Silvan Tank Specifications
M.A.W.P: 150 PSI @ 450 degrees Farenheight
M.D.M.T: -20 degrees Farenheight @ 150 PSI
Year Built: 1996
Cust Part No.: PV-1054
Head: 243
Shell: 250
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
What pressure, flow and temperature is it rated for?
This dryer is rated for 2600 SCFM at 150 PSIG maximum pressure with a purge pressure of 55 PSIG. The included Silvan tank has an M.A.W.P. of 150 PSI at 450°F and an M.D.M.T. of -20°F at 150 PSI. Note that heatless regenerative dryers typically achieve their rated capacity at 100°F inlet temperature and 100 PSIG operating pressure; capacity will derate with higher inlet temperatures or pressure drop, so confirm your actual operating conditions meet this unit's rating.
What should I inspect before putting it into service?
Inspect the desiccant condition in both towers—the 825 lbs per tower of AA2/5 and MC 4A may need replacement depending on service history and storage conditions. Check all pneumatic valves for cycling operation, verify the control system functions through a complete regeneration cycle, and inspect the Silvan tank for current hydrostatic test certification (pressure vessels typically require requalification every 5-10 years depending on jurisdiction). Confirm all pressure gauges, dewpoint monitoring ports, and safety relief devices are present and functional, and check tower head bolting and gaskets for any signs of leakage or corrosion.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.