Mobile Vaporizer 55 MCFH / 700psi for LNG / LOX / LIN / LAR
NewSpecifications
Description
Mobile Vaporizer 55 MCFH / 700psi for LNG / LOX / LIN / LAR
New 2025 CCH Equipment ReGasPro 55M mobile ambient air vaporizer, skid-mounted on a 30-foot trailer for lease. Rated for 55 MCFH at 700 psi design pressure, capable of vaporizing LNG, LN2, LOX, and LAR. Aluminum finned tubing welded to ASME B31.3 code with Class 300 RF flanges, galvanized steel frame, no external power required.
Brand new 2025 Cryogenic Vaporizer ReGasPro 55
Technical Specifications
Flow Capacity: up to 55 MCFH
Test Pressure: 770 psi
Max Design pressure: 700 psi
Service: LNG, LN2, LOX, LAR
Design: -320F
Material: Aluminum tubing welded to ASME B31.3 code
Inlet / Outlet Connections: Class 300 RF Flange
Base: Galvanize Steel Frame
Hybrid Fins Designed for Maximum Surface Area
Customized Outfit Available to Meet Project Needs
Galvanized skid-based install on chassis or dropped on surface
Trailer length: 30 Feet.
"Plug and Play Solution" - simply connect, no welding required.
No External Power Source Required
Designed to operate in series or to alternative between vaporizers
This is a very simple set up for your cryogenic regasification project needs. Just hook up your LNG / other cryo gas trailer and send the gas through this vaporizer. The trailer will deliver a flow rate of around 55,000 scfh for 8 hours straight. It will require about 8 hours of defrosting before it can be used for the next 8 hours.
Based on the project requirements the skid can be designed with onboard pumps, odorizers, flow meters, and any other requirements your project may have. We have most of the components in stock and can provide you with a quick solution for your project.
For short- or long-term lease ONLY!
Local inspections are welcome and the closest airport to us is DFW or Dallas Love Field Airport. We can help with shipping within the USA, North and South America, and other continents through a sea port of your choice.
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
How do I size this vaporizer for my flow rate and duty cycle?
This unit is rated for 55 MCFH output. The listing states it will deliver approximately 55,000 scfh for 8 hours straight, then requires about 8 hours of defrosting before it can be used for the next 8 hours. If you need continuous flow without interruption, you'll need two units operating in alternating duty, which the listing notes this vaporizer is designed to support.
What happens to output in cold or humid conditions, and on continuous duty?
Ambient air vaporizers typically derate significantly in cold weather because heat transfer depends on the temperature difference between ambient air and cryogenic liquid; capacity can drop 30–50% or more below freezing. High humidity accelerates frost buildup on the fins, reducing effective surface area and further cutting capacity. The listing indicates this unit requires 8 hours of defrosting after 8 hours straight of operation, which is consistent with batch duty operation rather than true continuous service in most climates.
Can this be put into a different gas service than it previously ran?
This is a new 2025 unit with no prior service history. Generally, ambient vaporizers rated for oxygen service (like this unit, which lists LOX compatibility) are built to oxygen-clean standards and can handle inert gases, but converting a unit that previously ran hydrocarbons or LNG into oxygen service requires complete cleaning, inspection, and recertification due to ignition risk. The listing states this unit is rated for LNG, LN2, LOX, and LAR from new.
What should I inspect on a used ambient vaporizer before buying?
This unit is listed as new, so typical used-equipment concerns don't apply here. On used ambient vaporizers generally, inspect fin-to-tube welds for cracks from thermal cycling, check aluminum tubing for corrosion or pitting especially at weld zones, verify flange faces are flat and undamaged, and confirm ASME code stamping and any required oxygen-service documentation is present and legible. Frost patterns during a live test can reveal internal flow restrictions or partial tube blockages.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.