GP:50 Model 336 Compact Differential Pressure Transducer – 0–10 INWCD | 4–20 mA Output
Technical Specifications
GP: 50 Model 336 Compact High-Accuracy Differential Pressure Transducer, part of a precision-engineered family of digitally compensated transducers designed for demanding industrial and laboratory applications. This unit measures 0–10 INWCD differential pressure and outputs a 4–20 mA signal, with 9–36 VDC excitation. Compact, rugged construction with digital compensation provides superior accuracy and long-term stability for process control, HVAC systems, cleanroom monitoring, filtration systems, test stands, and industrial automation.
Technical Specifications
Model: GP:50 Model 336
Pressure Range: 0–10 INWCD (Inches of Water Column Differential)
Excitation Voltage: 9–36 VDC
Output Signal: 4–20 mA
Key Features
- Digitally compensated design for superior accuracy and long-term stability
- Compact, rugged construction suitable for space-constrained installations
- Wide voltage excitation range for easy integration with control systems
- Industrial-grade 4–20 mA output for reliable signal transmission over long distances
- Ideal for low differential pressure measurement in critical applications
Applications
Perfect for process control, HVAC systems, cleanroom monitoring, filtration systems, test stands, and industrial automation where precision differential pressure measurement is required.
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
What pressure, flow and temperature is it rated for?
This unit measures 0–10 INWCD differential pressure with 9–36 VDC excitation and 4–20 mA output. The listing does not specify temperature range or flow capacity; ask the seller for the full environmental and operating temperature limits, as these vary by sensor design and housing configuration. Differential pressure transducers do not measure flow directly but are commonly used with orifice plates or venturis where flow is calculated from the differential reading.
What should I inspect before putting it into service?
Verify calibration against a known standard across the 0–10 INWCD range, checking both zero and span. Inspect pressure ports for debris or damage, test for leaks at both high and low ports, confirm electrical connections are clean and the 4–20 mA output tracks correctly with applied differential pressure, and verify the unit holds zero with ports equalized. If this was in storage, check that the sensing diaphragm has not stiffened or degraded and that digital compensation circuitry initializes properly on power-up.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.