Gas Detector- Honeywell XNX Transmitter W/ Honeywell Poole BH17 ORZ UK
NewSpecifications
Description
Gas Detector- Honeywell XNX Transmitter W/ Honeywell Poole BH17 ORZ UK
Honeywell XNX Universal Transmitter paired with a Honeywell Poole BH17 ORZ UK sensor, new condition. The XNX is rated for Class 1, Div. 1 Groups B, C & D and Class 1, Zone 1, Groups 2B+H2 hazardous locations, operating on 18 to 32 VDC with Pmax of 13.2w and ambient temperature range of -40°C to 65°C (Temp Code T6). Sensor part number is 2108B2201N.
Honeywell XNX Transmitter Description
XNX Universal Transmitter for use in Class 1, Div. 1 Groups B, C &D; Class 2, Div. 1 Groups F&G
18 to 32 VDC Max. Pmax= 13.2w
Class 1, Zone 1, Groups 2B+H2 Haz Loc. Tamb: -40 degrees Celsius to 65 degrees Celsius Temp Code T6 Class 2 Zone 20 & 21
Honeywell Poole BH17 ORZ UK:
Part No. 2108B2201N
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
What pressure, flow and temperature is it rated for?
The XNX transmitter has an ambient operating temperature range of -40°C to 65°C with a T6 temperature code. Gas detection systems typically do not have pressure or flow ratings in the traditional sense, as the sensor is exposed to ambient atmospheric conditions in the monitored area rather than installed inline.
What materials are the wetted parts?
The listing does not provide material specifications for the sensor housing or exposed components. Gas detectors do not have wetted parts in the process equipment sense, but the sensor and housing materials matter for chemical compatibility with the monitored environment. Contact the seller for the sensor housing material and whether it is suitable for your specific atmosphere and any corrosive or reactive gases present.
What should I inspect before putting it into service?
Verify the sensor part number 2108B2201N is calibrated for your target gas and that calibration is current, as detectors typically require calibration every 6-12 months depending on the gas and environment. Confirm the hazardous area classification markings match your installation requirements (Class 1 Div 1 or Zone 1 as applicable), inspect all cable glands and enclosure seals for integrity, and perform a bump test with known concentration gas to verify sensor response. Check that the power supply meets the 18-32 VDC requirement and that the 13.2W draw is within your loop budget.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.