Endress+Hauser PMP71
UsedSpecifications
Description
Endress+Hauser PMP71
Endress+Hauser PMP71 digital pressure transmitter with piezoresistive sensor and welded metallic membrane. Measuring range 5.8 PSI to 10,500 PSI with 100:1 turn-down ratio and ±0.05% reference accuracy. Outputs 4–20 mA with HART protocol for integration with process control systems.
Technical Specifications
Measuring Principle: Digital transmitter with piezoresistive sensor and welded metallic membrane
Output Signal: 4–20 mA with HART protocol
Supply Voltage
Non-Ex: 10.5–45 V DC
Ex ia: 10.5–30 V DC
Reference Accuracy: ±0.05% (Standard)
Process Temperature: -40°F to 257°F
Ambient Temperature: -58°F to 185°F
Measuring Range: 5.8 PSI to 10,500 PSI
Smallest Calibratable Span: 5 mbar (0.075 PSI)
Vacuum Resistance: 10 mbar (0.15 PSI)
Maximum Turn Down Ratio: 100:1
Maximum Overpressure Limit: 1050 bar (15,750 PSI)
Key Features
- High-accuracy measurement for critical process control
- Wide measuring range and exceptional turn-down capability
- Compact, rugged construction for harsh environments
- HART communication for integration with control systems
- Excellent temperature stability and repeatability
Applications
Perfect for oil & gas production, chemical processing, power generation, hydraulic systems, and industrial automation where precise pressure monitoring is essential.
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
What pressure, flow and temperature is it rated for?
This unit has a measuring range of 5.8 PSI to 10,500 PSI with a maximum overpressure limit of 15,750 PSI. Process temperature range is -40°F to 257°F, and ambient temperature range is -58°F to 185°F. This is a pressure transmitter, not a flow device—it measures static or dynamic pressure only.
What should I inspect before putting it into service?
Verify the membrane and process connection for corrosion, pitting, or damage from previous service, and confirm the electrical connections and housing are intact. Test the 4–20 mA output and HART communication against a calibrated reference across the intended span to verify it meets the ±0.05% accuracy specification. Check that the unit's calibration range matches your application—the 100:1 turndown allows field recalibration, but confirm current settings with a HART communicator before installation.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.