Cryoquip Ambient Air Vaporizer 100 GPM / 20,000 SCFH
UsedSpecifications
Description
Cryoquip Ambient Air Vaporizer 100 GPM / 20,000 SCFH
This is a Cryoquip HAF-825-FBL10 ambient air vaporizer built in 2011, designed for the vaporization of liquefied methane into gaseous natural gas. The unit utilizes finned ambient air heat exchange elements and is rated for 100 GPM flow at 450 PSIG maximum allowable working pressure. It carries ASME Code Stamp U with National Board Number 3094 and was previously operated in LNG service.
Vaporizer Description
This unit is a Cryoquip ambient air vaporizer designed for the vaporization of liquefied methane (LNG) into gaseous natural gas. The vaporizer utilizes finned ambient air heat exchange elements and is intended for cryogenic service where reliable phase change, pressure integrity, and continuous operation are required. The assembly is suitable for LNG fueling, storage, and industrial gas applications.
Manufacturer: Cryoquip Inc., Murrieta, California
Equipment Type: Ambient Air Vaporizer
Model: HAF-825-FBL10
Part Number: 4240101-1
Serial Number: 60092-1-1
Year Built: 2011
Condition: Used
Service Compatibility
LNG
Methane (CH₄)
Performance
Rated Flow: 100 GPM
Pressure and Temperature Ratings
Maximum Allowable Working Pressure: 450 PSIG @ 150°F
Minimum Design Metal Temperature: −320°F @ 450 PSIG
Electrical Specifications
Power: 4 kW
Voltage: 480
Phase: 3
Full Load Amps: 5
Codes and Certification
ASME Code Stamp: U
National Board Number: 3094
Certified By: Cryoquip Inc., Murrieta, CA
Notes
Unit is sold as-is.
Inspection availability and additional documentation to be confirmed.
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
How do I size this vaporizer for my flow rate and duty cycle?
This unit is rated for 100 GPM liquid flow. Ambient air vaporizers are typically sized with derating from nameplate on continuous duty to allow for frost buildup cycling and low-ambient conditions; actual delivered capacity depends on inlet pressure, ambient temperature, and whether your operation allows time for defrost cycles. For continuous uninterrupted flow in cold climates, many operators size conservatively or run multiple units in rotation.
What happens to output in cold or humid conditions, and on continuous duty?
Ambient vaporizers extract heat from surrounding air, so capacity drops significantly as ambient temperature falls. High humidity accelerates frost formation on the fins, which insulates the heat exchange surface and further reduces capacity until a defrost cycle clears it. On continuous duty without defrost intervals, expect sustained output well below the rated 100 GPM, particularly in winter or humid coastal conditions.
Can this be put into a different gas service than it previously ran?
This unit was previously operated in LNG service. Changing cryogenic service (e.g., LNG to LIN, LOX, or LAr) generally requires requalification to confirm material compatibility, pressure/temperature suitability, and cleaning to the purity standard of the new gas—oxygen service in particular demands specialized cleaning and materials verification that LNG service does not. The ASME Code Stamp U and National Board Number 3094 provide a basis for requalification, but you'll need the original design documentation and a qualified inspector to confirm suitability for any service other than methane.
What should I inspect on a used ambient vaporizer before buying?
Inspect the finned tubes for mechanical damage, corrosion, or prior frost-jacking distortion, and check all brazed or welded joints for cracks, particularly at tube-to-header connections where thermal cycling concentrates stress. Verify the nameplate, ASME stamp, and National Board Number 3094 are legible and request the original U-1 manufacturer's data report and any operating or hydrostatic test records since commissioning in 2011. The listing notes that inspection availability and additional documentation are to be confirmed, so ask the seller specifically for access to inspect the heat exchange bundle and for copies of the data reports before committing.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.