UsedSpecifications
ManufacturerAdvance Tank Mfg
ModelCryogenic 600 Gallon on 20 ft Goose neck trailer
Year1961
ConditionUsed
Capacity500 gallons
Pressure Rating250 PSIG
Gas ServiceLiquid Nitrogen (LIN), Liquid Argon (LAR)
LocationWaxahachie, TX, United States
Stock #GE4S-1267
Description
This is a 500-gallon ASME Section VIII, Div. 1 certified pressure vessel manufactured by Advance Tank MFG. Co. in 1961, mounted on a 20 ft gooseneck trailer and configured for LIN/LAR service. The vessel is built from heavy-duty welded carbon steel with a Maximum Allowable Working Pressure of 250 PSI and a Minimum Design Metal Temperature of –20°F at 250 PSI. The unit is fully ASME stamped, spot X-ray tested, and hydrostatically tested, with National Board Number 17706.
Specifications:
Manufacturer: Advance Tank MFG. Co.
Capacity: 500 Gallons
Maximum Allowable Working Pressure (MAWP): 250 PSI
Minimum Design Metal Temperature (MDMT): –20°F at 250 PSI
Shell Thickness: 0.143 in.
Head Thickness: 0.250 in.
Year Built: 1961
Serial Number: 11865
National Board (N.B.) Number: 17706
Material: SA-Steel, fully ASME stamped and inspected
Testing: SPOT X-Ray, Hydrostatic Tested
Features:
ASME Section VIII, Div. 1 Certified
Heavy-duty welded carbon steel construction
Spot X-Ray tested for quality assurance
Built for industrial processes, gas storage, or cryogenic system integration
Long service life with durable design
Questions buyers ask
What is the current vacuum reading, and what is the NER?
The listing does not provide current vacuum performance or Normal Evaporation Rate data. For a vessel built in 1961, vacuum degradation is common and these figures are essential to assess usability—request a recent vacuum gauge reading in microns and NER in gallons per day or percentage of capacity. On older cryogenic vessels, expect vacuum space contamination that may require re-evacuation or perlite replacement.
Is the data plate legible, and is the U-1A available?
The listing confirms ASME Section VIII, Div. 1 certification with National Board Number 17706, but does not state whether the physical nameplate is readable or whether the U-1A manufacturer's data report is on file. Both documents are critical for inspection, recertification, and jurisdictional acceptance—request photos of the nameplate and a copy of the U-1A before committing to purchase.
What is involved in relocating and re-commissioning it?
The unit is a gooseneck trailer-mounted vessel located in Waxahachie, TX, requiring a fifth-wheel-equipped truck for transport and compliance with DOT and state regulations for wide load or oversize permits depending on trailer width. Re-commissioning typically involves jurisdictional pressure vessel inspection, vacuum system evaluation, relief valve recertification, and potentially vacuum pump-down or insulation repair if NER is out of spec. Confirm the trailer's road-worthiness, DOT compliance, and current registration status with the seller.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.
Inspection, shipping & payment
Inspection
Pre-purchase inspections are welcome during normal business hours by appointment arranged in advance. We can provide complimentary transportation from DFW Airport and back if you would like to send someone to see the equipment in person. We can also walk through the item over a video call for domestic or international buyers. We are on US Central Time.
Shipping and loading
The equipment is located at our yard south of Dallas, Texas. We can assist with shipping arrangements.
Loading is provided at no charge for equipment under 15,000 lb when scheduled in advance. Equipment over 15,000 lb requires a crane, which is arranged and paid for by the buyer.
Payment
Payment in full is required FOB our yard in South Dallas. A verifiable cashier's check is accepted for collection in person. For release to a third-party shipper we require a wire transfer cleared in our account before the equipment leaves the yard.
Terms set by Gas Equipment 4 Sale.