CPI 1-Ton I-Beam Frame ASME NB Vessel — 10.1 cu ft, 7,252 PSIG
Specifications
Description
CPI 1-Ton I-Beam Frame ASME NB Vessel — 10.1 cu ft, 7,252 PSIG
CPI high-pressure vessel on a one-ton I-beam frame, ASME NB coded, 10.1 cubic feet of water volume at 7,252 PSIG. Built in 2023.
Technical Specifications
Manufacturer: CPI
Code: ASME NB
Water Volume: 10.1 cu ft
MAWP: 7,252 PSIG
Year: 2023
Outer Diameter: 16"
Dimensions: 128" x 24" x 24"
Nitrogen Capacity: 4,019 SCF
Hydrogen Capacity: 3,950 SCF
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
What is the current vacuum reading, and what is the NER?
The listing does not provide vacuum insulation performance data or normalized evaporation rate for this tank. For cryogenic hydrogen service, you'll want to request the current vacuum level (typically measured in microns or torr) and NER as a percentage of capacity per day—these are critical metrics that should be verified before purchase, especially on a recently manufactured vessel that may not have service history to demonstrate long-term insulation performance.
Is the data plate legible, and is the U-1A available?
The listing confirms ASME NB certification but does not address data plate condition or documentation availability. You should verify that the nameplate is intact and legible, and request the U-1A Manufacturer's Data Report and any form U-1B for post-construction work—these documents are essential for jurisdictional acceptance and any future modifications or recertification.
What is involved in relocating and re-commissioning it?
The unit is 128" tall with a 24" x 24" base footprint and is noted as ready for WAX coating, suggesting it may require surface preparation or protection for transport. High-pressure cryogenic vessels typically require vacuum pump-down and leak testing after relocation to verify insulation integrity, along with recalibration of pressure relief devices and instrumentation—allow for rigging and transport considerations given the height, and confirm with your jurisdiction whether a post-installation inspection or notification is required for the ASME NB code.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.