Air Products 20,000 Gallon Liquid Nitrogen Storage Tank – 70 PSI – LOX Equipment
UsedSpecifications
Description
Air Products 20,000 Gallon Liquid Nitrogen Storage Tank – 70 PSI – LOX Equipment
This is a 20,000 gallon horizontal cryogenic storage tank built by Lox Equipment Company for Air Products in 1988, designed for liquid nitrogen service at 70 PSIG design pressure. The tank features vacuum-insulated, double-walled construction with a carbon steel outer jacket and stainless steel inner vessel, certified to ASME Section VIII, Division 1. Serial number 30174, National Board number 3723, manufactured in Delphi, Indiana.
Technical Specifications
Manufacturer: Air Products / Lox Equipment Company
Tank Serial Number: 30174
National Board Number: 3723
Year Built: 1988
Capacity: 20,000 Gallons (Liquid Nitrogen)
Design Pressure: 70 PSIG
Operating Pressure: 50 PSIG
Autovent Set Pressure: 60 PSIG
Tank Safeties: 65 PSIG
Full Trycock: 78 Inches
Construction: Double-walled, vacuum insulated
Orientation: Horizontal bulk storage tank
Location of Manufacture: Delphi, Indiana
Heavy-duty carbon steel outer jacket with stainless steel inner vessel.
Designed for cryogenic nitrogen service under ASME Section VIII, Division 1.
Equipped with fill line connections, economizer, rupture discs, pressure regulators, and safety relief valves per Air Products’ engineering standards.
Bottom-fill system with venting controls for safe transfer operations.
Integrated instrumentation panel including pressure indicator, liquid level gauge, economizer, vaporizer, and multiple shutoff valves.
Multiple safety devices: burst discs, relief valves, and economizer protection.
Food and beverage freezing and preservation
Semiconductor and electronics manufacturing
Metal processing and heat treatment
Laboratory and research facilities
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
What is the current vacuum reading, and what is the NER?
The listing does not provide a current vacuum reading or NER (Normal Evaporation Rate) for this tank. Request these figures from the seller along with the date of last vacuum measurement, as vacuum degradation is the primary performance indicator on double-walled cryogenic tanks and determines whether the unit needs re-evacuation before service. On tanks of this vintage, NER above 1.5-2% per day typically indicates vacuum loss requiring service.
What product has it held, and what can it be converted to?
This tank was in liquid nitrogen service. Nitrogen tanks can generally be converted to liquid argon without modification, as both are inert and have similar temperature ranges (-320°F for nitrogen, -303°F for argon). Conversion to liquid oxygen requires ASME review and typically involves cleaning to oxygen service standards and possible materials compatibility assessment, as oxygen is highly reactive and requires rigorous contamination control.
Is the data plate legible, and is the U-1A available?
The listing confirms the serial number (30174) and National Board number (3723), which indicates the data plate information is readable. The listing does not state whether the ASME U-1A Manufacturer's Data Report is available; request a copy from the seller, as the U-1A is required for jurisdictional review and many states will not permit installation without it on file.
What is involved in relocating and re-commissioning it?
Relocation requires purging, warming to ambient temperature, vacuum relief, draining ancillary piping, crane lifting (typically 25,000-35,000 lbs for a 20,000-gallon horizontal tank including saddles and insulation), and transport on a lowboy or flatbed. Re-commissioning involves foundation preparation, saddle leveling and anchoring, vacuum integrity testing, pressure testing per ASME requirements, recalibration of relief devices set at 65 PSIG, and jurisdictional inspection if required by the state. Vacuum quality determines whether re-evacuation is needed before the tank can hold rated capacity without excessive boil-off.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.