700 PSI 15,000 SCFH N2 Vaporizer
NewSpecifications
Description
700 PSI 15,000 SCFH N2 Vaporizer
CCH Equipment Co VPC-15K-AL-16-4X4-P-15-06 ambient air vaporizer rated for 15,000 SCFH nitrogen capacity at 700 PSIG design pressure. This is a 2022 unit in new condition with 1-1/2" T&G flange connections, measuring 48" x 48" x 209" and weighing 750 lbs. Hydro tested to 770 PSI.
1-1/2" T&G Flange
Technical Specifications
Capacity SCFH N2: 15,000
Design PSI: 700
Test PSI: 770
Dimensions: 48" x 48" x 209"
Weight: 750
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
Is this sized for my peak demand or my average?
Ambient air vaporizers should be sized for peak demand, not average flow, because they have no stored heat capacity and their output drops significantly when ambient temperature falls or when inlet LN2 temperature is lower than design assumptions. This unit is rated at 15,000 SCFH N2, but the listing does not specify the ambient temperature or inlet conditions at which that capacity applies, so confirm those design parameters with the seller to verify it meets your peak with appropriate safety margin.
What are the installation and utility requirements?
Ambient air vaporizers require no utility connections—they rely entirely on natural convection and ambient air temperature for heat input. This unit has 1-1/2" T&G flange connections, measures 48" x 48" x 209", and weighs 750 lbs, requiring adequate vertical clearance and foundation support for that footprint and height. The listing does not specify mounting orientation, seismic certification, or minimum clearance to walls or obstructions, so request an installation drawing or manual from the seller.
What should I inspect on a used vaporizer before buying?
This unit is listed as new condition, but typical inspection points on any ambient vaporizer include fin condition (corrosion, physical damage, blockage from debris or ice), tube-to-header joints for evidence of leaks or prior repair, and flange faces for damage or improper gasket seating. Request documentation of the hydro test referenced in the listing (770 PSI), verify the nameplate matches the described model and pressure rating, and confirm no dents, frozen/burst sections, or evidence of overpressure or thermal stress if the unit was ever placed in service.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.