1960 U.S. Steel DOT 107A Tube Trailer – 2400 PSI MAWP – 180 CU FT (5097 Liters)
UsedSpecifications
Description
1960 U.S. Steel DOT 107A Tube Trailer – 2400 PSI MAWP – 180 CU FT (5097 Liters)
This 1960 DOT 107A tube trailer features U.S. Steel tubes mounted on a heavy-duty trailer frame, rated for a Maximum Allowable Working Pressure of 2,400 PSI and a hydro test pressure of 3,730 PSI. The system offers a total water volume of 180 nominal cubic feet (≈ 5,097 liters) and is suitable for inert gases including nitrogen, helium, argon, or compressed air. Most recently retested in February 2023 by TEA Technologies using ASTM E 1419-02b and ASTM E 2223-02 acoustic emission and ultrasonic methods, with the next retest due in February 2028.
The system offers a total water volume of 180 nominal cubic feet (≈ 5,097 liters), making it suitable for a wide range of inert gases including nitrogen, helium, argon, or compressed air.
The trailer was most recently retested in February 2023 by TEA Technologies (Amarillo, TX) using ASTM E 1419-02b & ASTM E 2223-02 acoustic emission and ultrasonic methods, with the next retest due in February 2028.
Technical Specifications
Manufacturer: U.S. Steel (tubes)
Year Built: 1960
Specification: DOT 107A
MAWP: 2,400 PSI
Test Pressure: 3,730 PSI
Total Water Volume: 180 CU FT (5,097 Liters)
Service: Inert Gases (Nitrogen, Helium, Argon, Air, etc.)
Latest Retest: 02/2023 (TEA Technologies, Amarillo, TX)
Next Retest Due: 02/2028
Compliance: ASTM E 1419-02b & ASTM E 2223-02
Frame: Heavy-duty steel trailer, DOT-certified
Condition: Certified, tested, and service-ready
Built in 1960 with robust U.S. Steel construction
Recertified and service-ready through 2028
Tested to ASTM and DOT standards for industrial gas use
Cost-effective bulk gas storage and transport option
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
What is the requalification status, and when is the next test due?
This trailer was retested in February 2023 by TEA Technologies using ASTM E 1419-02b and ASTM E 2223-02 acoustic emission and ultrasonic methods, with the next retest due in February 2028. DOT 107A tube trailers typically require requalification every five years, though the interval depends on the specific CFR requirements and any state or insurance mandates that may apply to your operation.
What is the actual gas capacity at service pressure?
The listing states a total water volume of 180 cubic feet (5,097 liters) and a MAWP of 2,400 PSI, but does not provide the actual gas capacity at working pressure. To calculate storage capacity for your gas, ask the seller for the number of tubes, individual tube volumes, and the specific working pressure you intend to operate at—then apply the compressibility factor for your gas of interest.
What gas service has it been in, and what can it be converted to?
The listing describes it as suitable for inert gases including nitrogen, helium, argon, or compressed air, but does not specify what service it has actually been in. Ask the seller for the complete service history, as previous contents dictate cleaning and purging requirements—oxygen service conversion, for example, requires rigorous degreasing and certification, while switching between dry inert gases is typically straightforward.
What should I inspect on a used tube trailer before buying?
Verify the retest documentation is complete and that all tube serial numbers match the certification paperwork, then visually inspect for external corrosion, road rash, and frame cracks especially near tube mounts and suspension points. Check all valves, manifolds, and pigtails for leaks and operability, examine tire condition and brake function, and confirm the DOT certification plate is legible and intact. On a 1960-vintage unit, pay close attention to tube-to-manifold connections and any signs of previous repair welds, as fatigue cracking becomes more likely with age.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.