19,500 SCFH 600 PSI Cryogenic Vaporizer
UsedSpecifications
Description
19,500 SCFH 600 PSI Cryogenic Vaporizer
CryoQuip VAI-H16-FBL20 cryogenic vaporizer rated for 19,500 SCFH at 600 PSIG MAWP. Temperature range is -320°F minimum to +150°F maximum. Three units available with serial numbers 28838-1-5, 28838-1-3, and 28838-1-2.
Technical Specifications
Rating: 19,500 SCFH
MAWP: 600 PSIG
Minimum Temp: -320 degrees F
Maximum Temp +150 degrees F
S/N: 28838-1-5
S/N: 28838-1-3
S/N: 28838-1-2
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Have one like this? Sell it on Metal Mountain →
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.
Questions buyers ask
Is this sized for my peak demand or my average?
Vaporizers are typically sized to meet peak instantaneous demand, not average flow, because gas withdrawal events tend to be abrupt and process-critical. At 19,500 SCFH, this unit will deliver that flow continuously under rated conditions, though ambient vaporizers can derate in cold weather or high humidity. Ask the seller whether your peak demand calculations should account for environmental derating factors specific to Waxahachie, TX.
What are the installation and utility requirements?
The listing does not provide dimensional, weight, or utility connection specifications. Ambient vaporizers like this typically require only inlet/outlet piping connections and adequate ventilation clearance, with no external utilities, but fin height, footprint, and flange sizes vary. Request certified drawings, nozzle schedules, and shipping weight from the seller to confirm compatibility with your pad and piping.
What should I inspect on a used vaporizer before buying?
Inspect fin-to-tube bonds for separation or corrosion, particularly at the lower headers where moisture accumulates, and check all welds and tube sheets for cracks from thermal cycling. Verify pressure vessel certification is current and request hydrostatic test records; ambient vaporizers operating near -320°F are subject to embrittlement and the MAWP stamping must match your application. If the units have been idle, internal moisture contamination is common and should be addressed before service.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.