IN HBVP-54K-AL — 54,000L Cryogenic Storage ISO Frame Unit
Specifications
Description
Questions buyers ask
What is the current vacuum reading, and what is the NER?
The listing does not provide the current vacuum reading or net evaporation rate for this unit. Request documentation showing recent vacuum measurement in microns and the NER in percentage per day, as these are the primary indicators of insulation performance and remaining service life on a used cryogenic tank.
Is the data plate legible, and is the U-1A available?
The listing does not confirm data plate condition or whether the ASME U-1A manufacturer's data report is available. Both are necessary for re-registration, hydrostatic testing, and jurisdictional acceptance, so request photos of the nameplate and copies of the U-1A and any Form U-3 reports from previous recertifications before proceeding.
What is involved in relocating and re-commissioning it?
The unit is located in Waxahachie, TX and measures 40' x 8' x 9'6", making it transportable as a standard 40-foot ISO container via flatbed or chassis. Re-commissioning typically requires hydrostatic testing if the vessel is out of certification, vacuum verification to confirm insulation integrity, replacement of pressure relief and control valves that may have exceeded calendar life, and leak testing of all piping and flanged connections per CGA standards.
General guidance for this type of equipment. Ask about this specific unit in your inquiry — the seller answers directly.
Inspection, shipping & payment
Terms set by Gas Equipment 4 Sale.
Price on Request
Seller
Gas Equipment 4 Sale
Waxahachie, TX, United States
Business and location confirmed by Metal Mountain.